Product

US-802  Snapper、Snap Action
CMJ・UL・C-UL・VDE(EN(60730A)approved

80201
◆More detailed image → Click the image

Features
Microminiature, slim, space-saving thermostat (with temperature sensor) ideal for printed circuit boards (PCB)
Application
LCD projector, power supply equipment, printed circuit board (PCB), etc.

PDF Catalog

  • 80202
Thermostat Specifications
Electrical ratings 125 VAC, max. 1A, resistance load
‐‐ (min. 200mA)
48 VDC, max. 1A, resistance load
‐‐ (MIN. DC5V 1mA)
Ⅰ.Temperature setting rangeⅡ.Temperature toleranceⅢ.Differential  Ⅰ.Temperature setting range
40・45・50 ・・・ ~ 120℃
(5K indent)
 Ⅱ.Temperature tolerance
±4℃/±7℃
 Ⅲ.Differential
15K
Circuit resistance(initial value) 50 mΩ or less
Insulation resistance 100 MΩ or greater [through the 500 VDC megger]
Withstand voltage 1,200 VAC/minute
Thermal resistance            125℃
Cold resistance            -20℃
Opening-closing durability 10,000 times or more [under rated load]

※Please contact specification of the approved models are slightly different from those shown above.

Model code
US-802 □□□
1 2 3
1 Model A :  Standard
2 Contact model X : “OFF” for temperature rise
Y : “ON” for temperature rise
3 Operating temperature   Example  085 : 85℃

Sample of Model code

  • US-802AX085 ・・ temperature rise, operate temp. 85℃±5℃, contact open ” OFF “
  • US-802AY095 ・・ temperature rise, operate temp. 85℃±5℃, contact close ” ON “

Standard Calibrations ( Open temperature / Close ) temperature

US-802AX Type (Open on temperature rise) / Limit US-802AY Type (Close on temperature rise) / Fan
MODEL CODE Operate Temp. ℃ OFF
±5K
Reset Temp. ℃ ON
±7K
MODEL CODE Operate Temp. ℃ OFF
±7K
Reset Temp. ℃ ON
±5K
802AX040 40 25 802AY040 25 40
802AX045 45 30 802AY045 30 45
802AX050 50 35 802AY050 35 50
802AX055 55 40 802AY055 40 55
802AX060 60 45 802AY060 45 60
802AX065 65 50 802AY065 50 65
802AX070 70 55 802AY070 55 70
802AX075 75 60 802AY075 60 75
802AX080 80 65 802AY080 65 80
802AX085 85 70 802AY085 70 85
802AX090 90 75 802AY090 75 90
802AX100 100 85 802AY100 85 100
802AX105 105 90 802AY105 90 105
802AX110 110 95 802AY110 95 110
802AX115 115 100 802AY115 100 115
802AX120 120 105 802AY120 105 120

List of international safety standards

Model / Type Agency File No. Operating
temp.
Ratings
Number of cycles Max. Max. Amperes
Category cycles Volts
Resistiveload
Inductiveload
FLA LRA
US-802 UL
C-UL
E52529 120 limiting 30,000 DC 48 1
AC 125 1
US-802-LC UL
C-UL
E52529 120 S.O.D. 1 DC 48 1
AC 125 1
US-802 VDE 40011726 120 thermostat 30,000 DC 48 1
100,000 DC 5 0.02
US-802-LC 120 S.O.D. 1 DC 48 1

Dimensional outline drawing

 ◆More detailed image → Click the image
802zu01802zu02

118602603621622623625628630802828
 ↑ Link